Ac-tive® IVF - N
Specifications:
External Workstation Dimensions
- Height (excluding stand): 1024 mm
- Width (side to side): 1650 mm
- Depth: 760 mm
- (additional 150mm required behind workstation for piping)
Internal Workstation Dimensions
- Height: 590 mm
- Width: 1174 mm
- Depth: 570 mm
Workstation Weight
- Weight approx: 230kg
Interlock Dimension
- Height: 210 mm
- Width: 270 mm
- Depth: 200 mm
Atmosphere Control
- Temperature: Ambient + 5°C- 45°C
- Humidity Control: Ambient-85%
- O2 Control: 0.0%-20.9%
- CO2 Control: 0.0%-30.0%
- Integrated HEPA Filtration System
- Activated Carbon Filtration System
Alarms
- Temperature: Visual and Audible
- Humidity: Visual
- Gas Low Pressure: Visual and Audible
Downloads/Links:
Downloads:
- Ac-tive®(IVF)-N System A4 product sheet
Ac-tive®(IVF)-N 'lab in a box' is a totally incubated workstation providing precise ‘in utero’ conditions for oocyte washing, culture preparation, fertilisation process, continuous embryo culture and embryo transfer.
Features and Benefits
'Lab in a Box'
Reduces need for laminar air flow cabinets and CO2 incubators
Stress-Free Embryology
Now embryologists can work 'In Utero' conditions. Stable O2, CO2, pH, temperature and humidity for all manipulations, mixing and culturing steps
Direct-Hand Access into Workstation
Using sterilised and user friendly cuff & sleeve system (Ezee Sleeve™)
Aids Compliance with EU TCD (2004/23/EU)
VOC filtration and HEPA filtration create a biologically safe working environment
CE (1293) Approved (MDD 93/42/EEC)
Compliant with European EMC and electrical safety tests
Standard Accessories
Workstation
- Stand
- 2 Racks with Perforated Shelves to Optimise Homogeneity
- Direct-hand Access using Ezee Sleeve™ and Ezee Pleez System
- Removable Front with UV Filtration Screen
- Waste trays
- Gas tight waste port
Gas Control Software
- USB Communications Port
- 7 Days Continuous Storage of Event Log Data
- One Touch Calibration (O2)
- On-Screen Fault Assistance
Optional Accessories
- Cable Gland Port to allow the passage of cables through the workstation wall without altering internal conditions
- Vacuum Line Port to allow the attachment of a vacuum line used to remove waste media from plates and dishes without removing them from the hypoxic conditions inside the workstation
- Gas Sample Port to enable samples of the Workstation atmosphere to be checked
- Gas Tank Regulators
- Gas Tank Filter Modules
- Power Failure Backup System maintains the hypoxic environment inside workstation if there is a mains power failure
- Vibration Isolation Platform designed to minimise vibration originating from the Workstation or Laboratory Floor; can be used for vibration free incubation of microtitre plates, dishes or flasks
- Adjustable incubation tray so that any micro-titre plates, flasks or dishes are kept absolutely level during incubation
- Adjustable chair
- Remote Monitoring Module allows users to be alerted by text message when gas pressure of O2 and gas pressure of CO2, temperature or humidity levels are out of specification
- Remote Monitoring Module allows users to be alerted by text message when gas pressure of O2 and gas pressure of CO2, temperature or humidity levels are out of specification
- Choice of "Free Flow" incubation racks
1: 150mm deep x 220mm tall x 460mm wide
2: 150mm deep x 320mm tall x 290mm wide - Gas Level Verification Meter (Geotech 100) designed to monitor CO2, and O2 inside Ruskinn Workstations, works under high humidity
Markets
- Assisted Conception Laboratories
- Stem Cell Investigations
- Tumour Research